Tunnel Tractor Battery 563V420Ah
Tunnel Tractor Battery 563V420Ah
Designed to be "Deep-cycle" that means the battery system can be discharged until almost empty, voltage nominal 563V and energy is 236kWh.
-
Safe & Endurable
Self-developed BMS provides the ultmost protection to battery, compatible with major Inverter brands.
-
Smart BMS
The battery detection unit is installed in the battery pack, which can accurately and real-time detect the battery voltage, temperature, capacity and other conditions, which can fully improve the safety of the product.
-
10 Years Design Life
A-class battery cells, with the protection of BMS, the system can deliver up to 10 years servicelife.
-
Reliable
Longer lifespan Laser Welding Rigid tests before shipment.
-
Adaptable
Self-heating function, consistent and efficient at -20 to 50 degrees.
-
Intelligent Monitoring
Monitor the battery status at any time on the APP, while the LCD window displays real-time data, battery charging, discharge and other data at a glance.
-
LiFePO4
A+ Tier Cells
-
563V
Voltage
-
236kWh
Energy
-
≥3500
Battery Cycles
-
5years
Warranty
563V420Ah- EV Battery- Tunnel Tractor | |||
SPECIFICATIONS | |||
Rated Capacity | 420Ah | ||
Rated Energy | 236kWh | ||
Nominal Voltage | 563V | ||
Dimension | 2700*1300*875mm | ||
Weight | approx. 2.5T | ||
Color | Gray | ||
High Voltage Cable Length | 6.5m | ||
Low Voltage Cable Length | 6.5m | ||
Display Screen | 8mm | ||
Working Voltage | 440-640V | ||
Max. continuous charge Current | 336A | ||
Max. continuous discharge current | 420A | ||
10S Pulse Current | 630A | ||
Protection Level | IP65 | ||
Charging Port | 2pcs(R-1pcs, L-1pcs) | ||
Working Temperature | Charge: 0~55℃ | ||
Discharge: -20~60℃ | |||
Storage Temperature | 0~35℃ | ||
State of Charge(SOC) before Shipment | 60%~70% | ||
Life Cycles | ≥2000 @25℃ | ||
BATTERY MANAGEMENT SYSTEM(BMS) PARAMETERS | |||
Contexture | 1BMU(Primary)+8CSC(Secondary) | ||
BMU Working Voltage | 24V | ||
BMU Power Consumption | <100mA | ||
BMU Total Voltage Collecting Range | 0~700V | ||
BMU Total Voltage Collecting Precision | 5V | ||
BMU Total Current Collecting Range | ±1000A | ||
BMU Total Current Collecting Precision | 1% | ||
BMU SOC Precision | 5% | ||
BMU Protection | Battery Protection: Charge/Discharge/Temperature/Current/Voltage | ||
Electrical Protection: Communication/Open Circuit/Short Circuit | |||
High voltage safety: insulation/contactor sintering, etc. | |||
CSC Single Unit Voltage Detecting Range | 0~5V | ||
CSC Single Unit Voltage Detecting Precision | ±5mV | ||
CSC Temperature Detecting Range | -40~125℃ | ||
CSC Temperature Detecting Precision | ±5℃ | ||
PROTECTION PARAMETERS | |||
High Temperature Alarm | >60℃ | Alarm level3: extremely high temperature | serious!cut off the charge & discharge |
>55℃ | Alarm level2: very high temperature | general alarm | |
>50℃ | Alarm level1:high temperature | general alarm | |
Low Temperature Alarm | <-20℃ | Alarm level3: extremely low temperature | serious! stop charging, cut off the charge & discharge |
<-15℃ | Alarm level2: very low temperature | general alarm | |
<-10℃ | Alarm level1: low temperature | general alarm | |
Temperature Difference Alarm | >20℃ | Alarm level3:extremely big difference | serious! cut off the charge & discharge |
>15℃ | Alarm level2:very big difference | general alarm | |
>10℃ | Alarm level1: big difference | general alarm | |
Over-voltage Alarm | Single Cell>3.75V | Alarm level3: extremely high voltage | serious! cut off the charge & discharge |
Single Cell>3.70V | Alarm level2: very high voltage | general alarm | |
Single Cell>3.66V | Alarm level1: high voltage | general alarm | |
Low Voltage Alarm | Single Cell<2.70V | Alarm level3:extremely low voltage | serious! cut off the charge & discharge |
Single Cell<2.90V | Alarm level2: very low voltage | general alarm | |
Single Cell<3.00V | Alarm level1: low voltage | general alarm,Recharge is required! | |
Total High Voltage Alarm | Total Voltage>660V | Alarm level3: extremely high voltage | serious! cut off the charge & discharge |
Total Voltage>651V | Alarm level2: very high voltage | general alarm, stop charging. | |
Total Voltage>644V | Alarm level1:high voltage | general alarm | |
Total Low Voltage Alarm | Total Voltage<475V | Alarm level3:extremely low voltage | serious! cut off the charge & discharge |
Total Voltage<510V | Alarm level2: very low voltage | general alarm | |
Total Voltage<528V | Alarm level1: low voltage | general alarm | |
Insulation Alarm | Insulation Resistance<64KΩ | Alarm level3:extrememly weak insulation | serious! cut off the charge & discharge |
Insulation Resistance<321KΩ | Alarm level1: weak insulation | general alarm | |
Imbalance Alarm | Voltage Difference>1V | Alarm level3: extreme imbalance | serious! cut off the charge & discharge |
Voltage Difference>0.7V | Alarm level2: big imbalance | general alarm | |
Voltage Difference>0.6V | Alarm level1:imblance | general alarm | |
Low SOC Alarm | SOC Value<10% | Alarm level3:extremely low SOC | serious! Cut off the discharge |
SOC Value<20% | Alarm level2: very low SOC | general alarm,Recharge is required! | |
SOC Value<30% | Alarm level1:low SOC | general alarm | |
Big Discharge Current Alarm | >504A | Alarm level3: extremely big | serious! cut off the charge & discharge |
>483A | Alarm level2: too big | general alarm, 5seconds | |
>462A | Alarm level1:big | general alarm, 5seconds | |
Charging Current | >504A | Alarm level3: extremely big | serious! cut off the charge & discharge |
>483A | Alarm level2: too big | general alarm, 5seconds | |
>462A | Alarm level1:big | general alarm, 5seconds | |
BMS Error | Alarm level3: internal network communication error | serious! cut off the charge & discharge | |
Communication Error | Alarm level3:Charging communication error | serious! cut off the charge & discharge | |
Discharge Relay Error | Alarm level3 | serious! cut off the charge & discharge | |
Charge Relay Error | Alarm level3 | serious! cut off the charge & discharge |